This includes most northern u s.
Attic heating duct insulation. Table 1 shows effective r values for 8 inch round ducts at three attic insulation levels and three duct insulation levels r 4 2 r 6 and r 8. Use the type of metallic foil duct tape recommended by the insulation manufacturer to seal and hold the insulation in place. For pricing and availability. Click here to see energy star recommendations for flexible duct insulation r energystar flex.
Air ducts supply conditioned air from heating or air conditioning equipment into the living spaces of your home. The effective r value of a buried duct installation depends on the size of the ducts the r value of the duct insulation and the depth of the loose fill insulation. Reflectix r 21 100 sq ft unfaced reflective roll insulation 48 in w x 25 ft l item 13358. Where to install duct insulation insulate ducts located on roofs and on unconditioned spaces like the attic garage crawlspace or unfinished basement.
Attic insulation air sealing experts enjoy a more comfortable healthy and efficient home with quality attic insulation services. When insulating hvac ductwork use a foil faced fiberglass insulation with an r 6 or higher r value. Epa estimates that homeowners can save an average of 15 on heating and cooling costs or an average of 11 on total energy costs by air sealing their homes and adding insulation in attics floors over crawl spaces and accessible basement rim joists. I found instead a vintage 3 ton ac unit with 1 rigid insulation taped all over it and insulated flex duct snaking all over the poorly insulated attic.
She asked me to go into the attic to find the roof leaks or where the snow is blowing in through the soffits. If your rigid metal ductwork has any insulation it may already have enough. Methodology for estimated energy savings from cost effective air sealing and insulating. For an added layer of protection you can apply duct mastic to the tape and duct.
Unitherm ceramic bulk fiber 6 8 densities 2300f 24l x 18w x 18h 25 lbs r value 56 75 box for chimney and furnace insulation model bf 6 8 25 38 65. In a vented attic this can happen when the duct is in close proximity to conditioned space i e the ceiling and also thermally isolated from the hot attic beneath the ceiling insulation. Home comfort problems often start in the attic where poor insulation and numerous air leaks create problems for your heating and cooling system and make your home uncomfortable. In this case the temperature gradient between supply air and the ceiling can be such that the duct surface could be cooler than the local dew point.
Lower cooling requirements high heating requirements. R 6 to r 11 cold.