Attic Ventilation Requirements Irc
Air vent provides a complete line of ventilation products that meet the highest standards for quality and performance.
Attic ventilation requirements irc. The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process. R806 2 minimum vent area. Below is the attic ventilation section. Unless local and state rules override them the rules listed in the irc are the basis for all code requirements for residential housing.
Also when using a vapor retarder in an attic space irc 2012 limits the net free ventilation reduction from 1 150 to 1 300 for buildings in climate zones 6 7 and 8. The ventilation amount and opening size requirements can be found in section 806 roof ventilation of chapter 8 roof ceiling construction. 2015 international residential code for attic ventilation air vent inc. Nrca guidelines regarding attic ventilation nrca recommends designers provide at least 1 square foot of nfva for every 150 square feet of attic space 1 150 ventilation ratio.
The following are the requirements taken directly from the irc. The majority of the requirements related to attic ventilation have not changed much from the previous editions. Irc section r408 1 ventilation the irc prescriptions for venting crawl spaces are contained in section r408 in several paragraphs. Openings in roof framing members shall conform to the requirements of section r802 7.
Attic ventilation shall not be required when determined not necessary by the code official due to atmospheric or climatic conditions. Let owens corning roofing help you calculate exactly how much ventilation you will need for a healthy and balanced attic with our 4 step ventilation calculator. The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures. Every 3 years the international residential building code irc releases code updates.
Federal housing authority recommends a minimum of at least 1 square foot of attic ventilation evenly split between intake and exhaust for every 300 square feet of attic floor space. Enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters shall have cross ventilation for each separate space by ventilating openings protected against the entrance of rain or snow. Proper attic ventilation consists of a balance between air intake at your eaves soffits or fascias and air exhaust at or near your roof ridge. The minimum amount of attic ventilation remains 1 150 1 square foot of net free area for every 150 square feet of attic floor space.