Owing to their sturdy construction and optimum performance our provided axial flow fan test rig is well acknowledged among our clients.
Axial flow fan test rig. Power input to the dc motor is varied by means of a thyristor controlled dc drive to vary the rpm of motor. The section geometry of the test rig is rectilinear and its size is 880 mm 880 mm. The tunnel consists of bell mouth shaped entry to guide the air smoothly into settling chamber and stabilizes the air flow this follows working section for test section where various models can. Offered bangles can be availed by our valuable client s at most competitive prices.
Figure 2 is a schematic of the closed test loop rig which includes water. The axial flow velocity increases from the fan hub to the tip. A pitot tube is provided in the delivery line of the axial fan for static and. Figure 1 displays the test axial flow pump installed in a pump station laboratory at wuhan university wuhan china 24.
A rpm indicator with proximity sensor indicates the rpm if axial fan. The fan design is complemented. The flow direction is left to right shown in figure 2. Manufacturer of wind tunel equipment centrifugal blower test rig axial fan test rig wind tunnel offered by quality engineers ambala haryana.
Deepthi engineering offering axial flow fan test rig ट स ट र ग aero dynamic lab equipments in azad nagar bengaluru karnataka. The test fan was set at no. Then the model requires the statistical data of wall pressure fluctuations close to the trailing edge. Blades that maximize the volumetric flow rate contribution of the outer radii i e.
Ahsanullah university of science technology department of mpe design and construction of axial flow fan testing rig participants shahib abrar 11 02 08 034 sadia islam 11 02 08 038 rakib hossain 11 02 08 047 s m. The resulting blade geometry generates a given volumetric flow rate at the minimum fan tip speed. The fan test rig and total fan pressure measurements using an array of kiel probes were assessed and in good comparison to. By using the same method the trailing edge noise prediction model of amiet is extended to the rotating blades of an axial flow fan.
It is at inlet part of test rig so the static air of outside region flows into the test. Get contact details and address id. So a test rig allowing the acquisition of these data is designed then used for this work. This equipment comprises of a axial flow fan coupled to a dc motor.
Axial fan test rig. The influence of different uniform ambient flow fields at the inlet or outlet of industrial axial fans on their integral performance curves was investigated in a nonstandard fan test rig inside a wind tunnel test section. 1 in figure 2.